Prof. Kircher´s solution with the LINK Embrace Shoulder System
Pre-op

67-year-old male patient
Cuff tear arthropathy
Good bone quality
High degree of activity
High demands on
- Implant longevity
- Biologic fixation
- Reduction of scapular notching and wear
- Revision options
Post-op

Implantation of the LINK Embrace
StemlessRing Cage with the TrabecuLink structure for bone integration,
Eccentric PE-Glenosphere with 39 mm diameter and CoCr Reverse Insert with a 10° inclination
Result
Outstanding primary stability
Good ROM and function
No pain
Good internal/ external rotation

Prof. Jörn Kircher
Head of the Shoulder and Elbow Surgery Section ATOS Klinik Fleetinsel
Hamburg, Germany
Further case studies can be found via the QR code shown or via
www.linkembrace.com